Automated Angle Measurement System for Directions Transmission
https://doi.org/621.398.694.4-531.4
Abstract
The paper presents the results of development of an angle measurement system for measuring the angles between the normals to the mirrors setting the directions in space. The system operates in a dynamical mode with a continuously rotating platform on which an autocollimating null indicator is installed. The angles are measured by means of a holographic angle encoder installed on the rotor of the system. The results of the system testing and calibration are presented. The system is calibrated by comparing it to a reference optical polygon.
About the Authors
E. D. BokhmanRussian Federation
P. A. Ivanov
Russian Federation
R. A. Larichev,
Russian Federation
M. S. Nikolaev
Russian Federation
P. A. Pavlov
Russian Federation
Yu. V. Filatov
Russian Federation
S. B. Berkovich
Russian Federation
N. I. Kotov
Russian Federation
References
1. http://www. kip–guide.ru/Gyrotheodolites GUROMAT 3000.
2. http://www. gtk–leica.ru/ GUROMAT 5000.
3. Gaivoronskii, S.V., Berkovich, S.B., Kotov, N.I., Makhaev, A.Yu., Sadekov, R.N., and Tsodokova, V.V., An Automatic system for determining astronomical azimuth, Measurement Techniques, 2015, vol. 58, no. 3, pp. 280–285.
4. Burnashev, M.N., Pavlov, P.A., and Filatov, Yu.V., Development of precision laser goniometer systems, Quantum Electronics, 2013, vol. 43, no. 2, pp. 130–138.
5. Astrua, M., Ichim, D., Pennecchi, F., and Pisani, M., Statistical techniques for assessing the agreement between two instruments, Metrologia, 2007, vol. 44, no. 5, pp. 385–392.
6. Qin, S., Huang, Z., and Wang, X., Optical angular encoder installation error measurement and calibration by ring laser gyroscope, IEEE Transactions on Instrumentation and Measurements, 2010, vol. 59, no. 3, pp. 506–511.
7. Barinova, E.A., Gordeev, S.V., Ivashchenko, E.M., and Pavlov, P.A., Optophysical measurements: A method and the results of investigating the random error of an optical angle encode, Measurement techniques, 2011, vol. 54, no. 9, pp. 1075–1080.
8. Nikolaev, M. S., and Filatov, Yu. V., Methods of calibrating prisms with faces that have no reflective coating, using a dynamic goniometer, Journal of Optical Technology, 2011, vol. 78, no. 3, pp. 224–226.
9. Kinnane, M.N., Hudson, L.T., Henins, A., and Mendenhall, M.H. A simple method for highprecision calibration of long-range errors in an angle encoder using an electronic nulling autocollimator, 2015, Metrologia, vol. 52, no. 2, pp. 244–250.
10. Stone, J.A., Amer, M., Faust, B., and Zimmerman, J., Uncertainties in small-angle measurement systems used to calibrate angle artifacts, Journal of Research of the National Institute of Standards and Technology, 2004, vol. 109, no. 3, pp. 319–333.
11. Filatov, Yu.V., and Larichev, R.A., Influence of the topography of the reflecting surface on angular measurements using an autocollimator, Izvestiya SPbGETU "LETI", 2012, no. 3, pp. 90–97.
12. Larichev, R.A., and Filatov, Yu.V., An autocollimation null detector: Development and use in dynamic goniometry, Journal of Optical Technology, 2013, vol. 80, no. 9, pp. 554–557.
Review
For citations:
Bokhman E.D., Ivanov P.A., Larichev, R.A., Nikolaev M.S., Pavlov P.A., Filatov Yu.V., Berkovich S.B., Kotov N.I. Automated Angle Measurement System for Directions Transmission. Giroskopiya i Navigatsiya. 2019;27(2):95-105. (In Russ.) https://doi.org/621.398.694.4-531.4